Heavenly Solar DHW Solar Controller

$330.00

Tax includedShipping calculated at checkout

SKU: SHWP0043

Please Note

This controller is no longer being produced and is not available. The Senztek 1-2 controller is the best replacement option it has a digital display and comes with a new roof and tank sensor. The sensors will need to be changed when replacing this controller. Please click on the following link to the Senztek 1-2 controller

https://www.solarhotwaterparts.com.au/controllers/solar-hw-controllers/senztek-solastat-plus-1-2-solar-hot-water-sensor-controller


 

Heavenly Solar DHW Controller (controller only - sensors not included)

The original earlier Heavenly Solar hot water system models used DHW Solar Controllers. Later models used the Senztek Lite/Eco. Neither of these controllers have digital temperature display.  Unfortunately, this makes fault finding difficult. It is worth looking at new and improved types of controllers that are priced around the same value. In some circumstances, depending on the age of the system, it may be easier to replace all the Heavenly Solar components with a complete pump station. In the long run this can be a much cheaper option. Click here to view a complete pump station. 

Solar Hot Water Parts stock the Heavenly Solar DHW Controller.

The DHW Solar Controller is an Australian owned and made controller, which will work with any system on the market.

This controller was also used in the following brands of solar hot water systems, earlier on:

Douglas Solar; Aquamax; Hills Solar; Heavenly Solar; Endless Solar; Solar Power; Suntrap Solar

Overview

Replacement solar hot water spare parts are easy to find here at Solar Hot Water Parts and even easier to repair. The DHW Solar Controllers come with pre-programed settings. These controllers can be customised and the pre-set settings easily changed if required.

Features and Operations

The DHW Solar Controller has been specifically designed for domestic hot water installations. Using a purpose built solar panel, the controller will endeavour to heat the tank water to 75ºC, and hold it at this temperature. The controller does this by using sensors to sense both the solar panel and the tank water temperature. When the solar panel temperature rises 9ºC above the tank water, the controller will turn the pump ON to circulate the water through the solar panel. If the tank water reaches 75ºC, or the solar panel temperature decreases to within 5ºC of the tank water, the pump will turn OFF. There is also a built-in freeze protection which will turn the pump ON if the solar panel temperature decreases to 3ºC. The pump will turn OFF once the panel temperature has risen to 5ºC. This feature will avoid the solar panel and the pipe work freezing.

Additional features include:

Lights that indicate Power ON; Pump ON; Tank Sensor Error and Collector Sensor Error.

Specifications:

  • Maximum tank temperature 75ºC
  • Maximum collector temperature 250C
  • Freeze protection 3ºC to turn ON; 5ºC to turn OFF
  • Tank/Collector differential 9ºC to turn ON; 5ºC to turn OFF
  • Maximum load 240V ac 10 Amp

At Solar Hot Water Parts, we are continually extending our solar hot water spare parts catalogue to give you the best selection of solar hot water replacement parts to choose from.

We sell the widest range of spare parts to suit any solar hot water service, whether it be a flat plate panel collector or evacuated tube solar collector. The Solar Hot Water Parts range is now online and ready to order, with complete tech specs to ensure your seamless selection.

If you're unsure which part suits, simply contact us - click here

 


The DHWC Solar Controller has been specifically designed for domestic hot water installations. Using a purpose built solar panel, the controller will endeavour to heat the tank water to 75ºC, and hold it at this temperature. The controller does this by using sensors to sense both the solar panel and the tank water temperature. When the solar panel temperature raises 9ºC above the tank water, the controller will turn the pump ON to circulate the water through the solar panel. If the tank water reaches 75ºC, or the solar panel temperature decreases to within 5ºC of the tank water, the pump will turn OFF. There is also a built in freeze protection which will turn the pump ON if the solar panel temperature decreases to 3ºC. The pump will turn OFF once the panel temperature has risen to 5ºC. This feature will avoid the solar panel and the pipe work freezing.

 

Additional features include:

 

Lights that to indicate Power ON, Pump ON, Tank Sensor Error and Collector Sensor Error.

 

Specifications:

 

  • Maximum tank temperature 75ºC
  • Maximum collector temperature 250C
  • Freeze protection 3ºC to turn ON; 5ºC to turn OFF
  • Tank/Collector differential 9ºC to turn ON; 5ºC to turn OFF
  • Maximum load 240V ac 10 Amp